Socket x Spigot Single Expansion Joints with O-Ring

4 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring

Socket x Spigot Single Expansion Joints with O-Ring

5 Inch (in) Nominal Size Medium Wall Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring

Socket x Spigot Single Expansion Joints with O-Ring

5 Inch (in) Nominal Size Heavy Wall Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring

Socket x Spigot Single Expansion Joints with O-Ring

2 Inch (in) Nominal Size Extra Heavy Wall, Bullet Resistant ID Aboveground Single Expansion Joint with O-Ring

Socket x Spigot Single Expansion Joints with O-Ring

3 Inch (in) Nominal Size Extra Heavy Wall, Bullet Resistant ID Aboveground Single Expansion Joint with O-Ring
Brand N/A Champion Fiberglass®, Inc.
Type N/A Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring N/A Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring N/A Iron Pipe Size (IPS) Aboveground Single Expansion Joint with O-Ring N/A ID Aboveground Single Expansion Joint with O-Ring N/A ID Aboveground Single Expansion Joint with O-Ring
Style N/A Expansion
Nominal Size N/A 4 in N/A 5 in N/A 5 in N/A 2 in N/A 3 in
Wall Thickness N/A Standard Wall N/A Medium Wall N/A Heavy Wall N/A Extra Heavy Wall, Bullet Resistant N/A Extra Heavy Wall, Bullet Resistant
A N/A 4.61 in117 mm N/A 5.79 in147 mm N/A 5.85 in149 mm N/A 3.000 in76 mm N/A 4.0000 in102 mm
B N/A 12 in305 mm
L [Min] N/A 15 in381 mm
L [Max] N/A 23 in584 mm
Color N/A Black
Weight N/A 0.75 kg1.66 lb N/A 1.25 kg2.76 lb N/A 1.36 kg3.00 lb N/A 1.32 kg2.90 lb N/A 1.90 kg4.19 lb
Industry Standards/Certifications N/A Underwriters Laboratories (UL) N/A Underwriters Laboratories (UL) N/A N/A Underwriters Laboratories (UL) N/A Underwriters Laboratories (UL)
Application N/A N/A Used for more protection in 5" & 6" N/A Used for increased protection in 4" - 8" N/A Highest level of physical protection, Class 1 Div 2 & Class 1 Zone 2 Applications N/A Highest level of physical protection, Class 1 Div 2 & Class 1 Zone 2 Applications
Features N/A Most Commonly used. N/A Most Commonly used. N/A Most Commonly used. N/A N/A
Installation of Expansion Joints N/A
  • When the duct is shorter than 50 ft., no Expansion Joint needed
  • When the duct is between 50 ft. up to 200 ft., install one Expansion Joint at the mid point
  • If the duct is longer than 200 ft., install one Expansion Joint every 200 ft. apart
Note N/A All Expansion Joints have a yellow line on the nipple end of the joint for proper installation.