Print Back
"Klein® Tools MM400 is an auto-ranging multimeter that measures AC/DC voltage, AC/DC current, and resistance. It can also measure temperature, capacitance, frequency, duty-cycle, and test diodes and continuity. Klein Tools™ Test and Measurement product line was exclusively designed from the ground up by electricians for electricians. Years of field research, combined with extensive input from electricians across America, inspired the development of meters and electrical testers loaded with innovative, time-saving features."
Unit of Measure

Specifications

Standard

N/A CAT III 600 V

Brand

N/A Klein®

Type

N/A Digital Multimeter

UPC Code

N/A 92644690211

UNSPSC code

N/A 41113630

Style

N/A Digital

Display

N/A 4000 Count Liquid Crystal Display (LCD)

Batteries

N/A AAA

Included

N/A Includes Test Leads, Thermocouple with Adapter and Batteries.

Number of Batteries

N/A 2

Capacitance

N/A 200 µF

Operating Temperature [Min]

N/A -18 ºC0 ºF

Operating Temperature [Max]

N/A 538 ºC1000 ºF

Frequency [Min]

N/A 1 Hz

Frequency [Max]

N/A 500 kHz

Resistance

N/A 40 MO

Direct Current (DC) Current

N/A 10 A

Alternating Current (AC) Current

N/A 10 A

Alternating Current (AC) Voltage

N/A 600 V

Direct Current (DC) Voltage

N/A 600 V

Drop Protection

N/A 3.3 ft1 m

Weight

N/A 0.23 kg0.51 lb

Dimensions

Overall Length

N/A 1-25/32 in45.2 mm

Overall Width

N/A 3-1/6 in77.8 mm

Overall Height

N/A 6.000 in152.4 mm

Features

Features

N/A
  • "Measures up to 600 V AC/DC voltage, 10 A AC/DC current and 40 MO resistance".
  • CAT III 600V safety rating.
  • Built to withstand a 3.3' (1 m) drop and withstand daily wear and tear on the job site.
  • Low battery indicator and easily accessible battery compartment.
  • "For use in basic and controlled electromagnetic environments such as residential, business and light-industrial locations."
  • Do not attempt to measure resistance or continuity on live circuits.
  • Before each use verify meter operation by measuring a known voltage or current.

Note

Note

N/A Read, understand and follow all instructions, cautions and warnings attached to and /or packed with all test and measurement devices before each use.