Items |
60A-SW-10-S 6 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Belowground Straight Conduit with Straight Socket |
15A-SW-20-S 1 1/2 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Belowground Straight Conduit with Straight Socket |
10C-SW-10S 1 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket |
15C-SW-20-S 1 1/2 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket |
12C-SW-10-S 1 1/4 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket |
|||||
Description | N/A The straight socket system consists of an integral bell and spigot where the bell is bonded on. The spigot end easily slides into the belled end. This joining system is intended for use with Champion Fiberglass epoxy adhesive. | |||||||||
Brand | N/A Champion Fiberglass®, Inc. | |||||||||
Type | N/A Iron Pipe Size (IPS) Belowground Straight Conduit with Straight Socket | N/A Iron Pipe Size (IPS) Belowground Straight Conduit with Straight Socket | N/A Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket | N/A Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket | N/A Iron Pipe Size (IPS) Aboveground Straight Conduit with Straight Socket | |||||
Nominal Size | N/A 6 in | N/A 1 1/2 in38 mm | N/A 1 in25 mm | N/A 1 1/2 in38 mm | N/A 1 1/4 in | |||||
Wall Thickness | N/A Standard Wall | |||||||||
Average Outside Diameter | N/A | N/A 1.900 in48 mm | N/A 1.30 in33 mm | N/A 1.900 in48 mm | N/A | |||||
Outside Diameter Tolerance | N/A | N/A -0.018 in0.028 in-0.4 mm0.7 mm | N/A -0.018 in0.028 in-0.4 mm0.7 mm | N/A -0.018 in0.028 in-0.4 mm0.7 mm | N/A | |||||
Inside Diameter [Min] | N/A | N/A 1.760 in45 mm | N/A 1.175 in30 mm | N/A 1.760 in45 mm | N/A | |||||
Nominal Wall Thickness1 | N/A | N/A 0.070 in2 mm | N/A 0.070 in2 mm | N/A 0.070 in2 mm | N/A | |||||
Length (L) | N/A 10 ft | N/A 20 ft6.1 m | N/A 10 ft3 m | N/A 20 ft6.1 m | N/A 10 ft | |||||
Color | N/A Black | |||||||||
End Type | N/A Bell End | |||||||||
Weight | N/A | N/A 0.33 lb/ft0.49 kg/m | N/A 0.19 lb/ft0.28 kg/m | N/A 0.33 lb/ft0.49 kg/m | N/A | |||||
Industry Standards/Certifications | N/A Underwriters Laboratories (UL) | N/A Underwriters Laboratories (UL), Canadian Standards Association (CSA) | N/A Underwriters Laboratories (UL), Canadian Standards Association (CSA) | N/A Underwriters Laboratories (UL), Canadian Standards Association (CSA) | N/A Underwriters Laboratories (UL) | |||||
Features | N/A Most Commonly used. | |||||||||
General Information |
N/A
Fiberglass Conduit Specifications for Use Below Ground The conduit shall be fiberglass conduit, also known as Reinforced Thermosetting Resin Conduit (RTRC), manufactured using the single circuit filament winding process. Multi circuit windings are not allowed. The conduit shall have a winding angle as close as possible to 54.75 degrees. The resin system shall be epoxy based, with no fillers, using an anhydride curing agent. The fiberglass shall consist of continuous E-glass roving. The conduit shall not contain any halogen compounds containing chlorine, bromine, fluorine and iodine in more than trace amounts when burning. Conduit and elbows shall be manufactured from the same resin/hardener/glass systems manufactured by the same filament wound system. Fiberglass conduit fittings and accessories shall be manufactured using one of two manufacturing procedures. The first method shall use the same process, methods, and components as used to manufacture the fiberglass conduit. The second method shall use the compression molding process, Sheet Molding Compound (SMC), for the manufacture of the finished component. The SMC material shall be a vinyl ester resin with +30% reinforcement of glass. The glass fibers should be approximately 1" in length. The SMC material shall be fire resistant to UL 2515. Conduit shall be integral bell and spigot or bonded coupling and spigot. Conduit, elbows and fittings are specified for use throughout a temperature range of -60ºF (-51ºC) to 250ºF (121ºC). Manufacturer shall have a current Certificate of Compliance, issued by an independent and accredited company, with an ISO 9001:2008 Quality Management System. |
|||||||||
Note | N/A | N/A | N/A When ordering 10 ft (3.05 m) lengths, half of the order will be supplied with interference joint and half with straight socket joint. | N/A | N/A | |||||
|