Print Back
The interference joint system consists of an integral bell and spigot. The spigot end has a buttress type, male thread for easy installation. The belled end contains the mating female threads. The tapered buttress threads make it easy to join while giving it a high pull out strength of 1,000 lbs. The joint is concrete tight but not water tight.
Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
Unit of Measure
Items Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
50C-SW-10-I
5 Inch (in) Nominal Size and 10 ft Length Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
40C-SW-10-I
4 Inch (in) Nominal Size and 10 ft Length Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
40C-SW-20-I
4 Inch (in) Nominal Size and 20 ft Length Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
50C-MW-20-I
5 Inch (in) Nominal Size and 20 ft Length Medium Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Interference Joint Iron Pipe Sizes (IPS) Straight Conduits
50C-SW-20-I
5 Inch (in) Nominal Size and 20 ft Length Standard Wall Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Description N/A The interference joint system consists of an integral bell and spigot. The spigot end has a buttress type, male thread for easy installation. The belled end contains the mating female threads. The tapered buttress threads make it easy to join while giving it a high pull out strength of 1,000 lbs. The joint is concrete tight but not water tight.
Brand N/A Champion Fiberglass®, Inc.
Type N/A Iron Pipe Size (IPS) Aboveground Straight Conduit with Interference Joint
Nominal Size N/A 5 in N/A 4 in N/A 4 in102 mm N/A 5 in127 mm N/A 5 in127 mm
Wall Thickness N/A Standard Wall N/A Standard Wall N/A Standard Wall N/A Medium Wall N/A Standard Wall
Average Outside Diameter N/A N/A N/A 4.460 in113 mm N/A 5.572 in142 mm N/A 5.520 in140 mm
Outside Diameter Tolerance N/A N/A N/A -0.018 in0.028 in-0.4 mm0.7 mm N/A -0.028 in0.034 in-0.7 mm0.9 mm N/A -0.018 in0.028 in-0.4 mm0.7 mm
Inside Diameter [Min] N/A N/A N/A 4.320 in110 mm N/A 5.380 in137 mm N/A 5.380 in137 mm
Nominal Wall Thickness1 N/A N/A N/A 0.070 in2 mm N/A 0.070 in2 mm N/A 0.070 in2 mm
Length (L) N/A 10 ft3 m N/A 10 ft3 m N/A 20 ft6.1 m N/A 20 ft6.1 m N/A 20 ft6.1 m
Color N/A Black
End Type N/A Bell End
Weight N/A N/A N/A 0.72 lb/ft1.07 kg/m N/A 1.20 lb/ft1.79 kg/m N/A 0.90 lb/ft1.34 kg/m
Industry Standards/Certifications N/A Underwriters Laboratories (UL) N/A Underwriters Laboratories (UL) N/A Underwriters Laboratories (UL), Canadian Standards Association (CSA) N/A Underwriters Laboratories (UL), Canadian Standards Association (CSA) N/A Underwriters Laboratories (UL)
Application N/A N/A N/A N/A Used for more protection in 5" & 6" N/A
Features N/A Most Commonly used.
General Information N/A Fiberglass Conduit Specifications for Use Below Ground

The conduit shall be fiberglass conduit, also known as Reinforced Thermosetting Resin Conduit (RTRC), manufactured using the single circuit filament winding process. Multi circuit windings are not allowed. The conduit shall have a winding angle as close as possible to 54.75 degrees.

The resin system shall be epoxy based, with no fillers, using an anhydride curing agent. The fiberglass shall consist of continuous E-glass roving. The conduit shall not contain any halogen compounds containing chlorine, bromine, fluorine and iodine in more than trace amounts when burning.

Conduit and elbows shall be manufactured from the same resin/hardener/glass systems manufactured by the same filament wound system.

Fiberglass conduit fittings and accessories shall be manufactured using one of two manufacturing procedures. The first method shall use the same process, methods, and components as used to manufacture the fiberglass conduit. The second method shall use the compression molding process, Sheet Molding Compound (SMC), for the manufacture of the finished component. The SMC material shall be a vinyl ester resin with +30% reinforcement of glass. The glass fibers should be approximately 1" in length. The SMC material shall be fire resistant to UL 2515.

Conduit shall be integral bell and spigot or bonded coupling and spigot.

Conduit, elbows and fittings are specified for use throughout a temperature range of -60ºF (-51ºC) to 250ºF (121ºC).

Manufacturer shall have a current Certificate of Compliance, issued by an independent and accredited company, with an ISO 9001:2008 Quality Management System.
Note N/A When ordering 10 ft (3.05 m) lengths, half of the order will be supplied with interference joint and half with straight socket joint. N/A When ordering 10 ft (3.05 m) lengths, half of the order will be supplied with interference joint and half with straight socket joint. N/A N/A N/A
  • 1 Actual wall thickness is that required to meet the performance requirements for specifications. Other wall thicknesses are available by special request.